Technical Data Linear actuator Zip Chain Actuator With hypoid motor Brake Characteristics
With hypoid motor Brake Characteristics
1. ZCA35M・45M:0.2kW・0.4kW・0.75kW
Hypoid Motor | ||||
---|---|---|---|---|
Motor Output | 3 Phase | 0.2kW | 0.4kW | 0.75kW |
Brake model number | 3 Phase 200VAC | SLB02 | SLB04 | SLB07E |
Three-phase 400 V | SLB02 | SLB04V | SLB07E 180V | |
DC rectifier number | 3 Phase 200VAC | DM200D | ||
Three-phase 400 V | DM200D | DM400D | ||
Braking torque | Static friction torque N・m{kgf・m} |
1.96{0.2} | 3.92{0.40} | 7.35{0.75} |
Dynamic friction torque N・m{kgf・m} |
1.57{0.16} | 3.14{0.32} | 5.88{0.60} | |
Voltage | 3 Phase 200VAC | DC90V | ||
Three-phase 400 V | DC90V | DC180V | ||
Current at 20℃ A | 0.178 | 0.232 | 0.273(0.142) | |
Capacity at 20℃ W | 16 | 20.9 | 24.6(25.5) | |
Initial gap mm | 0.15~0.20 | 0.15~0.20 | 0.15~0.20 | |
Limit gap mm | 0.5 | 0.5 | 0.5 | |
Total braking workload J{kgf・m} | 1.85×108 {1.89×107} | 1.85×108 {1.89×107} | 3.66×108 {3.73×107} | |
Allowable start-up frequency times | 10 times/min | |||
Braking delay time (Reference value) S |
AC internal wiring | 0.15~0.21 | 0.14~0.17 | 0.20~0.24 |
AC external wiring | 0.09~0.12 | 0.06~0.09 | 0.10~0.13 | |
AC external operation | 0.09~0.12 | 0.06~0.09 | 0.10~0.13 | |
DC external wiring | 0.04~0.06 | 0.03~0.05 | 0.04~0.06 |
- Note 1) The rated torque represents the static friction torque and dynamic friction torque after fitting.
- Note 2) The braking delay time is included as a reference and may differ depending on the braking conditions, operating conditions, and individual differences. To shorten the braking delay time (for lifting equipment, etc.), using DC external wiring is recommended.
2. ZCA25M:60W・90W
Hypoid Motor Mini Series | |||
---|---|---|---|
Motor Output | 3 Phase | 60W | 90W |
Brake model number | 3 Phase | BXW-04-10M-05-90V | BXW-04-10M-10-90V |
DC rectifier number | 3 Phase | DM200D | |
Braking torque | Static friction torque N・m{kgf・cm} |
0.6{6.1} | 1.0{10.2} |
Dynamic friction torque N・m{kgf・cm} |
0.48{4.8} | 0.8{8.1} | |
Operating voltage (V) | 3 Phase | DC90V | |
Current (A) | 3 Phase | 0.076 | 0.111 |
capacity (W) | 6.8 | 10 | |
Gap amount (mm) |
Initial value | 0.05~0.25 | |
Limit value (three-phase) | 0.4 | ||
Total braking workload J{kgf・m} |
3 Phase | 16.5×106 {16.8×105} | 13.4×106 {13.7×105} |
Allowable start-up frequency times | 10 times/min | ||
Braking delay time (Reference value) S |
AC internal wiring | 0.08 | 0.08 |
AC external wiring | 0.04 | 0.04 | |
AC external operation | 0.04 | 0.04 | |
DC external wiring | 0.01 | 0.01 |