Technical Data  Linear actuator  Power Cylinder  Motor Specifications

Motor current value/brake current value (U Series, T Series, G Series )

Output ・Frame number Current values for the motor
(A)
Brake model number Current values for the brake
(A)
200V 200V 220V 400V 400V 440V 200V 200V 220V 400V 400V 440V
50Hz 60Hz 60Hz 50Hz 60Hz 60Hz 50Hz 60Hz 60Hz 50Hz 60Hz 60Hz
4P‐0.1kW 0.72
(2.76)
0.62
(2.60)
0.65
(2.84)
0.36
(1.38)
0.31
(1.27)
0.32
(1.41)
SBH01LP 0.18
0.27
0.18
0.27
0.19
0.29
0.18
0.27
0.18
0.27
0.19
0.29
Applicable model number LPG□070L/LPG□100L
LPT□250S/LPT□250L/LPT□500S
4P‐0.2 kW 1.3
(4.91)
1.1
(4.68)
1.1
(5.14)
0.63
(2.40)
0.55
(2.22)
0.56
(2.41)
SBH02LP 0.18
0.27
0.18
0.27
0.19
0.29
0.18
0.27
0.18
0.27
0.19
0.29
Applicable model number LPG□070M/LPG□100M/LPG□150L/LPG□300M
LPT□250M/LPT□500L/LPT□1000S
4P‐0.4 kW 2.4
(11.6)
2.1
(10.2)
2.1
(11.0)
1.2
(5.14)
1.1
(4.88)
1.1
(5.39)
SBH04LP 0.18
0.27
0.18
0.27
0.19
0.29
0.18
0.27
0.18
0.27
0.19
0.29
Applicable model number LPG□070H/LPG□070U/LPG□100H/LPG□100U/LPG□150M/LPG□150H/LPG□300L/LPG□300H
LPT□250H/LPT□500M/LPT□1000L/LPT□2000S
4P‐0.75 kW 3.9
(24.0)
3.5
(22.0)
3.4
(24.0)
1.9
(12.0)
1.7
(11.0)
1.7
(12.0)
SLB07LP 0.18
0.27
0.18
0.27
0.20
0.30
0.09
0.15
0.09
0.15
0.10
0.16
Applicable model number LPT□500H/LPT□1000M/LPT□2000L/LPT□4000S
LPU□6000S
4P‐1.5 kW 6.5
(49.0)
6.1
(45.0)
5.8
(50.0)
3.2
(24.5)
3.1
(22.5)
2.9
(25.0)
SLB15LP 0.18
0.29
0.18
0.29
0.20
0.32
0.09
0.15
0.09
0.15
0.11
0.16
Applicable model number LPT□1000H/LPT□2000M/LPT□4000L
LPU□6000L/LPU□8000S
4P‐2.2 kW 9.4
(63.7)
8.9
(58.2)
8.3
(63.0)
4.7
(31.8)
4.4
(29.1)
4.2
(31.5)
SLB22LP 0.18
0.29
0.18
0.29
0.20
0.32
0.09
0.15
0.09
0.15
0.11
0.16
Applicable model number LPT□2000H/LPT□4000M
LPU□6000M/LPU□8000L/LPU□12000L
4P‐3.7 kW 14.8
(104)
14.4
(87.9)
13.2
(98.0)
7.4
(52.0)
7.1
(43.9)
6.6
(49.0)
VNB371K
(NB-31186)
0.10
0.30
0.10
0.30
0.10
0.30
0.05
0.15
0.05
0.15
0.05
0.15
Applicable model number LPT□4000H
LPU□6000H/LPU□8000M/LPU□12000M/LPU□16000L
5.5kW 22.5
(221)
20.0
(184)
19.3
(207)
11.2
(110)
10.1
(92.9)
9.6
(103)
3.9/0.59
-
3.9/0.59
-
3.9/0.59
-
1.96/0.30
-
1.96/0.30
-
1.96/0.30
-
Applicable model number LPU□8000H/LPU□12000H/LPU□16000M/LPU□22000L/LPU□32000L
7.5kW 30.5
(237)
29.0
(200)
27.0
(216)
15.2
(118)
14.4
(99.3)
13.6
(108)
3.9/0.59
-
3.9/0.59
-
3.9/0.59
-
1.96/0.30
-
1.96/0.30
-
1.96/0.30
-
Applicable model number LPU□16000H/LPU□22000M/LPU□32000M/LPU□50000L
11kW 42.0
(306)
41.0
(217)
38.0
(243)
21.0
(153)
20.5
(108)
19.0
(121)
5.40/0.72
-
5.40/0.72
-
5.40/0.72
-
2.70/0.37
-
2.70/0.37
-
2.70/0.37
-
Applicable model number LPU□22000H/LPU□32000H/LPU□50000M
15kW 58.0
(464)
55.0
(390)
51.0
(428)
29.0
(232)
27.5
(195)
25.5
(214)
5.40/0.72
-
5.40/0.72
-
5.40/0.72
-
2.70/0.37
-
2.70/0.37
-
2.70/0.37
-
Applicable model number LPU□50000H
  • Note)
  • 1.The above values are rated current values of the motor and brake. The numerical value in parentheses is a start current value of the motor.
    As a power cylinder, the motor's allowable current is up to 1.2 times the motor's rated current value because it is designed for short-time duty operation.
  • 2.The rated current and the starting current values do not include the brake current values. (The value for the V phase. )
  • 3.A DC brake is used. The upper stage of the brake current value indicates a value on the primary side of the power module, and the lower stage indicates a value on the secondary side.
    (U Series )Brake current values on 5.5 kW and above are expressed in acceleration/holding.
  • 4.The above values are references because the rated current values for the power cylinder vary depending on the operating conditions.
  • 5.Please contact us for the motor current value/brake current value for V1 to V4.
  • 6.(T series, G series )For motor capacities from 0.1kW-0.4kW with a 400V Class power source, the voltage is converted to 200V and input through the motor’s center tap.
    For individual turnoff, decrease the voltage to 200 to 220V by a transformer.
    The capacity of the transformer capacity shall be 90VA or more.
  • 7.(T Series )When you use an external brake connection with 400V Class power source over 0.75kW, voltage reduction is unnecessary as the DC module is compatible with the 400V Class.
  • 8.(T Series )For 0.75kW, 1.5kW, 2.2kW and 3.7kW of 400V class, the brake model Nos. are “SLB07LPV”, "SLB15LPV", "SLB22LPV" and “VNB371K(NB-31187)” respectively.