Technical Data Linear actuator Power Cylinder Motor Specifications
Motor current value/brake current value (U Series, T Series, G Series )
Output ・Frame number | Current values for the motor (A) |
Brake model number | Current values for the brake (A) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
200V | 200V | 220V | 400V | 400V | 440V | 200V | 200V | 220V | 400V | 400V | 440V | ||
50Hz | 60Hz | 60Hz | 50Hz | 60Hz | 60Hz | 50Hz | 60Hz | 60Hz | 50Hz | 60Hz | 60Hz | ||
4P‐0.1kW | 0.72 (2.76) |
0.62 (2.60) |
0.65 (2.84) |
0.36 (1.38) |
0.31 (1.27) |
0.32 (1.41) |
SBH01LP | 0.18 0.27 |
0.18 0.27 |
0.19 0.29 |
0.18 0.27 |
0.18 0.27 |
0.19 0.29 |
Applicable model number | LPG□070L/LPG□100L | ||||||||||||
LPT□250S/LPT□250L/LPT□500S | |||||||||||||
4P‐0.2 kW | 1.3 (4.91) |
1.1 (4.68) |
1.1 (5.14) |
0.63 (2.40) |
0.55 (2.22) |
0.56 (2.41) |
SBH02LP | 0.18 0.27 |
0.18 0.27 |
0.19 0.29 |
0.18 0.27 |
0.18 0.27 |
0.19 0.29 |
Applicable model number | LPG□070M/LPG□100M/LPG□150L/LPG□300M | ||||||||||||
LPT□250M/LPT□500L/LPT□1000S | |||||||||||||
4P‐0.4 kW | 2.4 (11.6) |
2.1 (10.2) |
2.1 (11.0) |
1.2 (5.14) |
1.1 (4.88) |
1.1 (5.39) |
SBH04LP | 0.18 0.27 |
0.18 0.27 |
0.19 0.29 |
0.18 0.27 |
0.18 0.27 |
0.19 0.29 |
Applicable model number | LPG□070H/LPG□070U/LPG□100H/LPG□100U/LPG□150M/LPG□150H/LPG□300L/LPG□300H | ||||||||||||
LPT□250H/LPT□500M/LPT□1000L/LPT□2000S | |||||||||||||
4P‐0.75 kW | 3.9 (24.0) |
3.5 (22.0) |
3.4 (24.0) |
1.9 (12.0) |
1.7 (11.0) |
1.7 (12.0) |
SLB07LP | 0.18 0.27 |
0.18 0.27 |
0.20 0.30 |
0.09 0.15 |
0.09 0.15 |
0.10 0.16 |
Applicable model number | LPT□500H/LPT□1000M/LPT□2000L/LPT□4000S | ||||||||||||
LPU□6000S | |||||||||||||
4P‐1.5 kW | 6.5 (49.0) |
6.1 (45.0) |
5.8 (50.0) |
3.2 (24.5) |
3.1 (22.5) |
2.9 (25.0) |
SLB15LP | 0.18 0.29 |
0.18 0.29 |
0.20 0.32 |
0.09 0.15 |
0.09 0.15 |
0.11 0.16 |
Applicable model number | LPT□1000H/LPT□2000M/LPT□4000L | ||||||||||||
LPU□6000L/LPU□8000S | |||||||||||||
4P‐2.2 kW | 9.4 (63.7) |
8.9 (58.2) |
8.3 (63.0) |
4.7 (31.8) |
4.4 (29.1) |
4.2 (31.5) |
SLB22LP | 0.18 0.29 |
0.18 0.29 |
0.20 0.32 |
0.09 0.15 |
0.09 0.15 |
0.11 0.16 |
Applicable model number | LPT□2000H/LPT□4000M | ||||||||||||
LPU□6000M/LPU□8000L/LPU□12000L | |||||||||||||
4P‐3.7 kW | 14.8 (104) |
14.4 (87.9) |
13.2 (98.0) |
7.4 (52.0) |
7.1 (43.9) |
6.6 (49.0) |
VNB371K (NB-31186) |
0.10 0.30 |
0.10 0.30 |
0.10 0.30 |
0.05 0.15 |
0.05 0.15 |
0.05 0.15 |
Applicable model number | LPT□4000H | ||||||||||||
LPU□6000H/LPU□8000M/LPU□12000M/LPU□16000L | |||||||||||||
5.5kW | 22.5 (221) |
20.0 (184) |
19.3 (207) |
11.2 (110) |
10.1 (92.9) |
9.6 (103) |
3.9/0.59 - |
3.9/0.59 - |
3.9/0.59 - |
1.96/0.30 - |
1.96/0.30 - |
1.96/0.30 - |
|
Applicable model number | LPU□8000H/LPU□12000H/LPU□16000M/LPU□22000L/LPU□32000L | ||||||||||||
7.5kW | 30.5 (237) |
29.0 (200) |
27.0 (216) |
15.2 (118) |
14.4 (99.3) |
13.6 (108) |
3.9/0.59 - |
3.9/0.59 - |
3.9/0.59 - |
1.96/0.30 - |
1.96/0.30 - |
1.96/0.30 - |
|
Applicable model number | LPU□16000H/LPU□22000M/LPU□32000M/LPU□50000L | ||||||||||||
11kW | 42.0 (306) |
41.0 (217) |
38.0 (243) |
21.0 (153) |
20.5 (108) |
19.0 (121) |
5.40/0.72 - |
5.40/0.72 - |
5.40/0.72 - |
2.70/0.37 - |
2.70/0.37 - |
2.70/0.37 - |
|
Applicable model number | LPU□22000H/LPU□32000H/LPU□50000M | ||||||||||||
15kW | 58.0 (464) |
55.0 (390) |
51.0 (428) |
29.0 (232) |
27.5 (195) |
25.5 (214) |
5.40/0.72 - |
5.40/0.72 - |
5.40/0.72 - |
2.70/0.37 - |
2.70/0.37 - |
2.70/0.37 - |
|
Applicable model number | LPU□50000H |
- Note)
- 1.The above values are rated current values of the motor and brake. The numerical value in parentheses is a start current value of the motor.
As a power cylinder, the motor's allowable current is up to 1.2 times the motor's rated current value because it is designed for short-time duty operation. - 2.The rated current and the starting current values do not include the brake current values. (The value for the V phase. )
- 3.A DC brake is used. The upper stage of the brake current value indicates a value on the primary side of the power module, and the lower stage indicates a value on the secondary side.
(U Series )Brake current values on 5.5 kW and above are expressed in acceleration/holding. - 4.The above values are references because the rated current values for the power cylinder vary depending on the operating conditions.
- 5.Please contact us for the motor current value/brake current value for V1 to V4.
- 6.(T series, G series )For motor capacities from 0.1kW-0.4kW with a 400V Class power source, the voltage is converted to 200V and input through the motor’s center tap.
For individual turnoff, decrease the voltage to 200 to 220V by a transformer.
The capacity of the transformer capacity shall be 90VA or more. - 7.(T Series )When you use an external brake connection with 400V Class power source over 0.75kW, voltage reduction is unnecessary as the DC module is compatible with the 400V Class.
- 8.(T Series )For 0.75kW, 1.5kW, 2.2kW and 3.7kW of 400V class, the brake model Nos. are “SLB07LPV”, "SLB15LPV", "SLB22LPV" and “VNB371K(NB-31187)” respectively.