Technical Data  High-speed lifters  Zip Chain Lifter  Three-phase Motor Wiring and Lifting Direction

Three-phase Motor Wiring and Lifting Direction (for inverter only )

Three-phase Motor Wiring and Lifting Direction

Set the base frequency at 60 Hz.

(M):Motor  (B):Brake  MC:Magnetic contactor  MCa :Auxiliary relay

DM200D:DC rectifier  --N--:Protection element (Varistor )

Product name Company name Model No.
Surge Absorber Panasonic ERZV14D471
Zetrap Fuji Electric ENE471D-14A
Ceramic Varistor Nippon Chemi-Con TND14V-471KB00AAA0

※Zetrap is a registered trademark of Fuji Electric Device Technology.

Three-phase Motor Wiring and Lifting Direction
  • Note 1 The brake voltage is 90 VDC. (When inputting 200 VAC to DM200D )
  • Note 2 The brake power supply module can be damaged depending on the wiring length, wiring method, relay type, or other factors. Connect a varistor between the separate DC switching terminals.
    Connecting closer to the brake power supply module (blue lead wire) will be most effective. The specific model numbers of the varistors are as shown left. Select a varistor voltage of 470 V for DM200D.
    ※For *1 in the table above, use an auxiliary relay (MCa) with a contact capacity of 200 VAC / 7 A or more (resistive load).
  • Note 3 ※When using an MC auxiliary contact or auxiliary relay for *2 in the table above, use a device with a contact capacity of 200 VAC / 10 A or more (resistive load).
    ※*3 Use a supply voltage of 200-254 VAC at 0.1 kW, 200-230 VAC at 2.2 kW, or 200-220 VAC at 3.7 kW for the brake shown in the marked section.