Technical Data  High-speed lifters  Zip Master  Wire connection for motor

Three-phase Motor Wiring and Lifting Direction

Three-phase Motor Wiring and Lifting Direction

Three-phase Motor Wiring (for inverter only)

3.7kW

Three-phase Motor Wiring (for inverter only)

Set the base frequency at 60 Hz.

5.5kW

Three-phase Motor Wiring (for inverter only)

Set the base frequency at 60 Hz.

(M):Motor  (B):Brake  MC:Magnetic contactor  MCa :Auxiliary relay  OCR:Overcurrent relay

DM200D、PM180B:DC rectifier  --N--:Protection element (Varistor )

Product name Company name Model No.
Surge Absorber Panasonic ERZV14D471
Ceramic Varistor Nippon Chemi-Con TND14V-471KB00AAA0
  • Note 1 The brake voltage is 90 VDC. (When inputting 200 VAC to DM200D or PM180B )
  • Note 2 When using a 3.7 kW motor, the brake power supply module can be damaged depending on the wiring length, wiring method, relay type, or other factors. Connect a varistor between the separate DC switching terminals.
  • Note 3 For *1 in the diagram, use an auxiliary relay (MCa) with a contact capacity of 200 VAC / 7 A or more (resistive load).
    When using an MC auxiliary contact or auxiliary relay for *2 in the diagram, use a device with a contact capacity of 200 VAC / 10 A or more (resistive load).
  • Note 4 Connecting closer to the brake power supply module (blue lead wire) will be most effective. The specific models of the varistors are as follows. Select a varistor voltage of 470 V for DM200D.