Technical Data High-speed lifters Zip Master Wire connection for motor
Three-phase Motor Wiring and Lifting Direction

Three-phase Motor Wiring (for inverter only)
3.7kW

Set the base frequency at 60 Hz.
5.5kW

Set the base frequency at 60 Hz.
(M):Motor (B):Brake MC:Magnetic contactor MCa :Auxiliary relay OCR:Overcurrent relay
DM200D、PM180B:DC rectifier --N--:Protection element (Varistor )
Product name | Company name | Model No. | ||
---|---|---|---|---|
Surge Absorber | Panasonic | ERZV14D471 | ||
Ceramic Varistor | Nippon Chemi-Con | TND14V-471KB00AAA0 |
- Note 1 The brake voltage is 90 VDC. (When inputting 200 VAC to DM200D or PM180B )
- Note 2 When using a 3.7 kW motor, the brake power supply module can be damaged depending on the wiring length, wiring method, relay type, or other factors. Connect a varistor between the separate DC switching terminals.
- Note 3 For *1 in the diagram, use an auxiliary relay (MCa) with a contact capacity of 200 VAC / 7 A or more (resistive load).
When using an MC auxiliary contact or auxiliary relay for *2 in the diagram, use a device with a contact capacity of 200 VAC / 10 A or more (resistive load). - Note 4 Connecting closer to the brake power supply module (blue lead wire) will be most effective. The specific models of the varistors are as follows. Select a varistor voltage of 470 V for DM200D.