Technical Data Reducers Worm Gear Reducers Selection
Selection Chart (Single Reduction: 1/10 to 1/60 )
[Sizing Table 1 ]
Common for EWJ/EW/SWJ/SW Series
Input r/min | Reduction ratio | load kW | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |||||||||||||||
EWJ | SWJ | EWJ | SWJ | EWJ | SWJ | EWJ EW |
SWJ SW |
EWJ EW |
SWJ SW |
EWJ EW |
SW | EW | SW | EW | SW | EW | SW | EW | SW | EW | SW | EW | SW | EW | SW | ||
1750 | 10 | 35 | 35 | 50 | 50 | 63 | 70 | 80 | 80 | 80 | 100 | 125 | 125 | 125 | 150 | ||||||||||||
15 | 35 | 42 | 50 | 50 | 63 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 175 | ||||||||||||
20 | 35 | 42 | 50 | 63 | 70 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | 200 | ||||||||||||||
25 | 35 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 150 | 175 | 200 | - | |||||||||||||
30 | 35 | 50 | 50 | 63 | 63 | 70 | 80 | 100 | 100 | 125 | 150 | 175 | 175 | 200 | - | ||||||||||||
40 | 35 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | 200 | - | - | |||||||||||||
50 | 42 | 50 | 63 | 80 | 80 | 125 | 125 | 150 | 175 | 200 | - | - | - | ||||||||||||||
60 | 42 | 50 | 63 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||||
1450 | 10 | 35 | 35 | 50 | 50 | 63 | 70 | 80 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | ||||||||||||
15 | 35 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 175 | ||||||||||||||
20 | 35 | 42 | 50 | 63 | 80 | 80 | 100 | 125 | 125 | 150 | 175 | 175 | 200 | ||||||||||||||
25 | 35 | 50 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 175 | 200 | - | |||||||||||||
30 | 35 | 50 | 50 | 63 | 80 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | 200 | - | |||||||||||||
40 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | |||||||||||||
50 | 42 | 50 | 63 | 80 | 100 | 125 | 150 | 150 | 200 | - | - | - | - | ||||||||||||||
60 | 42 | 50 | 63 | 63 | 70 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||
1150 | 10 | 35 | 35 | 50 | 50 | 63 | 70 | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | ||||||||||||
15 | 35 | 42 | 50 | 63 | 63 | 70 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | 200 | |||||||||||||
20 | 35 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 150 | 175 | 200 | 200 | |||||||||||||
25 | 35 | 50 | 50 | 63 | 70 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | 200 | - | |||||||||||||
30 | 35 | 50 | 63 | 70 | 80 | 100 | 125 | 125 | 150 | 200 | 200 | - | - | ||||||||||||||
40 | 42 | 50 | 63 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | ||||||||||||||
50 | 42 | 50 | 63 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||||
60 | 42 | 63 | 70 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||||
950 | 10 | 35 | 42 | 50 | 63 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 175 | ||||||||||||
15 | 35 | 42 | 50 | 63 | 70 | 80 | 100 | 125 | 125 | 150 | 150 | 175 | 200 | ||||||||||||||
20 | 35 | 42 | 50 | 63 | 70 | 70 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | 200 | - | ||||||||||||
25 | 35 | 50 | 63 | 70 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | 200 | - | ||||||||||||||
30 | 35 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | 200 | - | - | |||||||||||||
40 | 42 | 50 | 63 | 80 | 100 | 125 | 125 | 150 | 200 | 200 | - | - | - | ||||||||||||||
50 | 42 | 63 | 63 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||||
60 | 50 | 63 | 70 | 100 | 125 | 125 | 150 | 175 | - | - | - | - | - |
Note) Sizing Table 1 is for the EWJ, EW, SWJ, and SW series. When selecting EWJM(R), EWM(R), SWJM(R), or SWM(R) series (with motor), the combination of reduction ratio and motor kW is standardized. Refer to the Motor and Reduction Ratio Combinations.
[Sizing Table 2 ]
Common for EWJ/EW/SWJ/SW Series
Input r/min | Reduction ratio | load kW | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |||||||||||||||
EWJ | SWJ | EWJ | SWJ | EWJ | SWJ | EWJ EW |
SWJ SW |
EWJ EW |
SWJ SW |
EWJ EW |
SW | EW | SW | EW | SW | EW | SW | EW | SW | EW | SW | EW | SW | EW | SW | ||
1750 | 10 | 35 | 42 | 50 | 50 | 63 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 175 | |||||||||||
15 | 35 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | 200 | |||||||||||||
20 | 35 | 50 | 50 | 70 | 70 | 80 | 80 | 100 | 125 | 150 | 150 | 175 | 200 | 200 | |||||||||||||
25 | 35 | 50 | 50 | 63 | 70 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | 200 | - | |||||||||||||
30 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 175 | 200 | - | - | |||||||||||||
40 | 42 | 50 | 63 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | - | - | - | ||||||||||||||
50 | 42 | 50 | 63 | 63 | 70 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||
60 | 42 | 63 | 70 | 80 | 100 | 100 | 125 | 175 | 175 | - | - | - | - | - | |||||||||||||
1450 | 10 | 35 | 42 | 50 | 50 | 63 | 63 | 70 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 175 | ||||||||||
15 | 35 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 175 | 175 | 200 | |||||||||||||
20 | 35 | 50 | 50 | 63 | 70 | 80 | 100 | 100 | 125 | 150 | 175 | 175 | 200 | - | |||||||||||||
25 | 35 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | - | - | |||||||||||||
30 | 42 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | 200 | - | - | |||||||||||||
40 | 42 | 50 | 63 | 70 | 80 | 100 | 125 | 150 | 150 | 200 | - | - | - | - | |||||||||||||
50 | 42 | 50 | 63 | 63 | 70 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||
60 | 50 | 63 | 70 | 80 | 100 | 100 | 150 | 175 | 200 | - | - | - | - | - | |||||||||||||
1150 | 10 | 35 | 42 | 50 | 63 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 150 | 150 | 175 | ||||||||||||
15 | 35 | 50 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 150 | 150 | 175 | 200 | 200 | |||||||||||||
20 | 35 | 50 | 50 | 63 | 70 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | 200 | - | |||||||||||||
25 | 42 | 50 | 50 | 70 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | 200 | - | - | |||||||||||||
30 | 42 | 50 | 50 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | ||||||||||||||
40 | 42 | 50 | 63 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | ||||||||||||||
50 | 50 | 63 | 63 | 70 | 80 | 100 | 125 | 150 | 175 | - | - | - | - | - | |||||||||||||
60 | 50 | 63 | 63 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | - | |||||||||||||
950 | 10 | 35 | 42 | 50 | 63 | 63 | 70 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | 200 | ||||||||||||
15 | 35 | 50 | 50 | 63 | 70 | 70 | 80 | 100 | 100 | 125 | 150 | 150 | 175 | 200 | - | ||||||||||||
20 | 35 | 50 | 63 | 70 | 80 | 80 | 100 | 125 | 125 | 150 | 175 | 200 | 200 | - | |||||||||||||
25 | 42 | 50 | 63 | 80 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | ||||||||||||||
30 | 42 | 50 | 63 | 80 | 100 | 125 | 125 | 150 | 200 | 200 | - | - | - | ||||||||||||||
40 | 42 | 63 | 63 | 70 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | |||||||||||||
50 | 50 | 63 | 70 | 80 | 100 | 100 | 125 | 175 | 200 | - | - | - | - | - | |||||||||||||
60 | 50 | 63 | 80 | 100 | 125 | 150 | 175 | 200 | - | - | - | - | - |
Note) Sizing Table 2 is for EWJ, EW, SWJ and SW series. When selecting EWJM(R), EWM(R), SWJM(R), or SWM(R) series (with motor), the combination of reduction ratio and motor kW is standardized. Refer to the Motor and Reduction Ratio Combinations.