Technical Data Linear actuator Power Cylinder Motor Specifications
Terminal box specifications (U Series 、T Series 、G Series )
Motor Capacity :0.1kW~3.7kW
Shape of terminal box | Motor Capacity | Connector | Applicable cable outer diameter | Connector part mounting dimension A | Terminal box seat hole dimension B |
---|---|---|---|---|---|
![]() (0.4kW or less ) |
0.1kW~0.4kW | SK-14L | Φ11~Φ13 | G½ {PF½} |
- |
![]() (0.75kW or more ) |
0.75kW~1.5kW | A20C | Φ14~Φ15 | G¾ {PF¾} |
Φ28 |
2.2kW~3.7kW | A25C | Φ19~Φ20 | G1 {PF1} |
Φ35 |
- Note)
1.A rubber plug or plate has been inserted into the connector to prevent water etc., from intruding before shipment. Make sure to remove it when using. The ground terminal size is M4. - 2.When using captire cable/lead wires outdoors, waterproofing must be sufficient.
- 3.Please contact us if you are considering using a cable with an outer diameter larger than the applicable cable outer diameter.
Motor Capacity :5.5kW~15kW
Shape of terminal box | Motor Capacity | Connector part mounting dimension | After M/G adapter conversion | |
---|---|---|---|---|
![]() |
5.5kW | For motor | 2×M32×1.5 | G1 |
For brakes | 1×M16×1.5 | G½ | ||
7.5kW | For motor | 2×M32×1.5 | G1 | |
For brakes | 2×M16×1.5 | G½ | ||
11kW 15kW |
For motor | 2×M40×1.5 | G½ | |
For brakes | 2×M16×1.5 | G½ |
- Note)
1. The cable entry port on the terminal box is a metric screw. One "conversion adapter" for converting to G thread is included for each motor and brake. - 2. When using captire cable/lead wires outdoors, waterproofing must be sufficient.
※Connector specification is also available Contact us for details.