Technical Data Coupling Sizing and procedure
To view selection procedures and precautions, please proceed to the following.
Click here to narrow down the product series or to make a tentative selection.
If you have specific conditions of use and wish to make a detailed selection, please click here.
Roller chain coupling Stainless steel series Selection
1. Operating conditions
- (1) Daily operating hours
- (2) Load characteristics and type of motor
- (3) Transmission power (kW) and rotation speed (r/min) or torque (N·m)
- (4) Outer diameters of both shafts
2. Selection Method
- (1) Obtain the service factor from the table of service factors on the right-hand side according to the operating conditions.
- (2) Multiply the transmission power (or torque) by the service factor and obtain the correction transmission power (or correction transmission torque).
- (3) Use the transmission capacity table to select a coupling that satisfies the correction transmission power (or correction torque) at the operating rotation speed. (See Table below. )
- (4) If the required shaft diameter exceeds the maximum shaft diameter of the coupling selected, adopt a coupling a size larger.
- (5) The contact pressure may become excessive if a standard key is used. Calculate the contact pressure of the key and consider the necessity of using a special key or spline.
Load characteristics | Motor type | ||||
---|---|---|---|---|---|
Motor Turbine |
Steam engine Gasoline engine (4 cylinders or more ) |
Diesel engine Gas engine |
|||
Low fluctuation, low impact, low starting torque, and no reverse rotation | 1.0 | 1.5 | 2.0 | ||
Middle fluctuation, middle impact, and no reverse rotation (standard load ) |
1.5 | 2.0 | 2.5 | ||
High fluctuation, high impact, reverse rotation, and loaded starting | 2.0 | 2.5 | 3.0 |
-
Note) 1. An increase according to the operating hour of the chain coupling (provided that the rotation speed is 50 r/min. or more )
8 to 16 hours/day ......0.5
16 hours or more/day ......1.0
- Note) 2. The above table shows rough service factor standards Decide on the service factor according to the operating conditions.
[Reference ]Relationship between torque, transmission, and rotation speed
T = 9550 × P n T = 974 × P n
- T:Torque N・m
- P:Power transmission kW
- n:Speed r/min
3. Backlash
Model No. | CR4012 | CR4014 | CR4016 | CR5014 | CR5016 | CR5018 | CR6018 | CR6022 | CR8018 | CR8022 | CR10020 | CR12018 | CR12022 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Backlash (deg) |
2.12 | 1.80 | 1.58 | 1.72 | 1.50 | 1.32 | 1.24 | 1.02 | 1.16 | 0.94 | 1.00 | 0.84 | 0.68 |
Note) The above figures are calculated value and not guaranteed.
4. Operating Temperature Range
Without case | With case | |
---|---|---|
Operating temperature (℃) | -20~200 | -10~80 |
Note) Contact Tsubaki for information about operation at temperatures above 80°C with the case.