Technical Data Reducers DCBL Hypoid Motor Handling
This section describes the general handling of DCBL Hypoid Motor & Driver.
For more information, see the instruction manual provided with the product.
Storage
If you will not be using a reducer for a while, store it under the following conditions.
1. Storage place
- Store indoors in a clean, dry place.
Do not store outdoors, in humid or dusty places, or in places subject to extreme temperature changes and corrosive gases.
2. Storage period
- (1) Do not store products for more than six months.
- (2) If products are to be stored for more than six months, they will require special rust-proofing specifications. Please contact Tsubaki.
3. Usage following storage
- (1) Non-metal parts such as the oil seal, oil gauge, and oil supply plug tend to deteriorate due to environmental factors. Inspect those sections before starting operation, and if there is any deterioration, replace with new parts.
- (2) When starting the motor, make sure there is no unusual noise, vibration, or heat generation. If there is, immediately contact the dealer.