Zip Chain Actuator Major Specifications
Model No. :ZCA35N100DR




[Click to enlarge ]
PDF Outline Drawing
DXF drawings / 3D CAD data
Contact us for details.
Standard Price
Contact us for details.
Delivery
Contact us for details.
Catalogs ・Instruction Manuals
- E-Book Catalog (Japanese) (LINEAR MOTION )
- E-Book Catalog (Japanese) (Zip Chain Actuator )
- E-Book Catalog (English) (Zip Chain Actuator )
- Instruction Manuals (Japanese)
- Instruction Manuals (English)
- Leaflet (Medium size design stock model )
- Leaflet (With DCBL Hypoid Motor )
- Leaflet (With TERVO (reducer for servo motors) )
Characteristics
| Allowable stroke mm ※1 |
Allowable Thrust N ※2 Upper row :No Bellows Lower row :With Bellows |
Maximum speed mm/s ※3 |
Maximum Input Speed r/min |
Allowable Torque on Input Shaft N・m |
Allowable overhang load N |
Amount of Zip Chain movement per input shaft rotation mm |
|---|---|---|---|---|---|---|
| 1000 | 600 | 1000 | 420 | 34.7 | 946 | 142.9 |
| 431 |
※1.Use the unit within the allowable stroke range. Also, be sure to always attach a linear guide in the direction of travel.
※2.Values represent basic performance with an end fixture attached. Values are for when operated at a maximum 0.35 G (upper limit) acceleration. These values are applicable regardless of the type of installation (vertical, horizontal, hanging).
※3.Zip Chain speed at maximum input rotation speed.
Table of Dimensions
| A mm |
B mm |
L mm Upper row :No Bellows Lower row :With Bellows |
Estimated Mass kg Upper row :No Bellows Lower row :With Bellows |
|
|---|---|---|---|---|
| min | max | |||
| 281 | 654 | 149 | 1149 | 8.5 |
| Contact us for details. | Contact us for details. | 9.0 | ||
Specification ・Operating Environment Standards
| Drive section | Material | Cast iron |
|---|---|---|
| Paint Color | Black, Munsell N2.0 equivalent | |
| Housing section | Material | Polyacetal |
| Paint Color | Purple gray Munsell 0.8P6.3/3.0 equivalent. (Molded) |
|
| Chain | Material | Steel |
| Lubrication | Shell Gadus S2 V220 J 2 (EP) 、Shell Lubricants Japan K.K. *Pre-sealed |
|
| Operating Environment Standards | Operating temperature | 0~60℃ |
| Relative Humidity | 85% or less (no condensation) | |
| Operating environments | Typical rain-free indoor environment with the amount of dust kept at a general factory level. | |
| Mounting direction | ZCAs can be used in lifting, horizontal, and hanging installations, but always provide a linear guide in the direction of travel. A mounting base is required for hanging installations. |
Options Sold Separately
Safety cap

[Click to enlarge ]
| Model No. | Standard Price | Delivery |
|---|---|---|
| ZCA35-CAP | Contact us for details. | Contact us for details. |
Contact Information